Price
$
Login
Item#
SK-5000B
已选清单
0种
0件
Description
Please click if you need => Slit Lamp.
Please click if you need => Optometry Table.
Features: | |||||||
*Fast,safe and convenient. | |||||||
*Touch lightly,3D automatic introcular pressure measurement for both eyes. | |||||||
*Air jet test:After the machine is turned on,check whether the measuring system of the instrument works normally. | |||||||
*Touch lightly,3D automatic introcular pressure measurement for both A267eyes. | |||||||
*It can monitor introcular pressure dynamically 24 hours,and print it on the same report sheet with intraocular pressure data. | |||||||
*The touch control screen can be turned 180 degree up and down,60 degree left and right,which is convenient for the operator to support the patient and lift the eyelid. | |||||||
*The accurate corneal thickness measurement function is provided to provide intraocular pressure compensation value and automatically calibrate the intraocular pressure value. | |||||||
*The machine can be connected to the database system through DICOM3.0 to archive and read the data,which conforms to the new era hospital standard. | |||||||
Specification | |||||||
SK-5000A | SK-5000B | ||||||
Measurement mode | Fully auto/auto/manuel | ||||||
Corneal thickness measurement | Not support |
Support Measurement range-CCT:400~800um Measurement increment-CCT:10um Light source:Blue LED |
|||||
Display | 7" 1024*600 color touch screen,Support up and down 180 degrees,left and right 60 degrees flip | ||||||
Fixation lamp | 1 internal fixation lamp(green LED); 2 external fixation lamps | ||||||
Measurement accuracy | 1mmHg(0.133Kpa) | ||||||
Measuring range | 0-60mmhg(0-8kpa)(including free switching between 30/60mmhg) | ||||||
Printer | Built in thermal printer,auto paper cutting. | ||||||
Data input and output | Input:USB;output:LAN/RS232C | ||||||
Size and weight | 500*300*500mm,<25kg. | ||||||
Measuring head moving range | Up and down stroke:45mm,left and right stroke:90mm,front and back stroke:40mm | ||||||
Lifting range of lower jaw drag | 68mm | ||||||
Working distance | 11mm(calculated from the front of nozzle) | ||||||
Power supply | AC100-240V,50/60HZ | ||||||
Ambient temperature | 50 dgrees | ||||||
Scope of operation | 16mmx10mm | ||||||
Data storage | Internal memory card+optional external USB memory | ||||||
Networking | DICOM3.0 | ||||||
Measurement mode | Fully automatic/automatic/manual | ||||||
Operating system | Embedded system | ||||||
Mobile platform | Fully automatic platform/manual platform | ||||||
Focusing mode | 3D full auto focus/manual focus | ||||||
Jet detection | After power on,check whether the measuring system of the instrument works normally | ||||||
Satety limit | Support | ||||||
Intraocular pressure measurement |
Each eye was measured three times continuously,and the average value was calculated. Normal intraocular pressure range:10-21mmhg(1.33kpa-2.80kpa) |
||||||
Full automatic measurement | Press the measurement button to complete the intraocular pressure test automatically. | ||||||
24-hour dynamic intraocular pressure measurement | It can monitor intraocular pressure dynamically 24 hours,and print it on the same report sheet with intraocular pressure data. | ||||||
Printing | Data can be printed directly after measurement | ||||||
Storage | 10 sets of measurement data can be stored | ||||||
Data export | Can be exported to PDF or JPG format |